Issue
- WINPE is failing to load drivers that have been injected.
- WINPE is corrupt and needs to rebuild it.
- Need to create a new BOOT.WIM.
- BOOT.WIM file is missing from the Managementsuite\LANDesk\VBOOT folder on the Core Server.
Resolution
- MOVE all of the following files on the Core Server to a Temp folder as a backup if they exist:
- Managementsuite\BOOT.WIM.BAK
- Managementsuite\BOOTMEDIA.WIM.BAK
- Managementsuite\BOOT_x64.WIM.BAK
- Managementsuite\LANDesk\VBOOT\BOOT.WIM.BAK
- Managementsuite\LANDesk\VBOOT\BOOTMEDIA.WIM.BAK
- Managementsuite\LANDesk\VBOOT\BOOT_x64.WIM.BAK
- Managementsuite\LANDesk\VBOOT\BOOT.WIM
- Managementsuite\LANDesk\VBOOT\BOOTMEDIA.WIM
- Managementsuite\LANDesk\VBOOT\BOOT_x64.WIM
- Copy BOOT.WIM and BOOT_x64.WIM from the Managementsuite\LANDesk\VBOOT\Clean folder to the Managementsuite\LANDesk\VBOOT folder on the Core Server.
- In Windows Explorer, right-click OSD.UPGRADE.EXE in the Managementsuite folder on the Core Server and select the "Run as administrator" option. This will open a command prompt window that will stay open until it is finished.
- When OSD.UPGRADE.EXE finishes, inject any required NIC or Disk Controller drivers into WINPE through the LANDESK Console.
- For 2016 and older versions, redeploy all PXE representatives. For 2016.3 and newer versions, wait for the PXE reps to automatically download the BOOT.WIM and BOOT_x64.WIM files from the Core Server.